If you own and live in your home, the usual guidance is to have an EICR at least every 10 years. An EICR, or Electrical Installation Condition Report, is a full inspection and test of your home's fixed wiring by a qualified electrician. No law says a homeowner must have one, but it is the only way to know for sure that wiring you can't see is still safe.
Ten years is the longest gap, not the target. This post explains where that figure comes from, when to book a check sooner, and how your last report tells you when the next one is due. It also covers one safety check you can make yourself, using only the test button on your consumer unit. Anything beyond that, such as taking off a socket faceplate or opening the consumer unit, is a job for a qualified electrician.
Where the 10-year guidance comes from
Electrical Safety First, the UK's electrical safety charity, recommends an inspection at least every 10 years for an owner-occupied home, and NICEIC gives the same advice. The figure comes from the guidance that sits alongside BS 7671, the national wiring regulations electricians work to.
Wiring rarely fails all at once. Cable insulation dries out with age and heat, connections loosen as they warm up and cool down, and over the years new sockets, lights and appliances get added to circuits that were never planned for them. A check every 10 years catches that slow wear before it turns into a fire or shock risk.
When to book one sooner
Many homes need a check well before the 10 years are up. It's worth booking one if:
you have just bought or moved into the home and the seller had no recent report
you are about to sell, as buyers and their surveyors often ask about the electrics
you don't know when the electrics were last checked, or you have never had a report
the wiring looks old, such as rubber or fabric-covered cable, a fuse box with a wooden back, or round-pin sockets
the home has had a flood or a serious water leak near cables or fittings
someone other than an electrician has done electrical work over the years
Warning signs are different. A burning smell, scorch marks on a socket, a switch that feels warm or a breaker that keeps tripping need looking at now, not at the next inspection. Stop using that circuit if you can and call an electrician.
Your last report tells you when the next one is due
Every EICR ends with a recommended date for the next inspection. The electrician sets it from what they found, so it can be sooner than 10 years. An older installation that is still safe but showing its age might be given five years, for example.
It's worth finding your last report and checking that date. Many electricians also put a small label on or near the consumer unit (the box with your main switch and circuit breakers, often still called the fuse box) showing when it was last inspected and when the next check is due. If you have had a rewire or a new consumer unit fitted, you should have an Electrical Installation Certificate instead, and that gives a date for the first inspection too.
If you rent the property out, the rules are stricter
For a home you let, an EICR is a legal requirement in England, not just advice. The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 say the installation must be inspected and tested at least every five years, or sooner if the last report says so. We cover what landlords need to know in our post on electrical inspection and testing for rented properties.
A safety check you can make yourself
Between inspections, one check is quick and safe: testing your RCDs. An RCD, or residual current device, is a safety switch in your consumer unit that cuts the power in a fraction of a second if current leaks to earth, for example through a damaged cable or a person. British Standards say RCDs should be tested every six months, and NICEIC suggests doing it when the clocks change in spring and autumn so it's easy to remember.
To test an RCD:
Tell everyone in the house first, and save anything open on a computer, as the power will go off on some circuits.
Press the button marked T or Test on the RCD.
The switch should drop to off straight away. Push it back up to on.
Reset any clocks and check the fridge and freezer have come back on.
If the RCD doesn't switch off when you press the button, or won't switch back on, leave it off and call an electrician. If your consumer unit has no RCD at all, that is a sign it is due for an upgrade, which we explain in our post on the signs you need a consumer unit upgrade.
You can also look, without touching, for cracked or scorched sockets, loose switch plates and cables worn where they run behind furniture. Never take off covers or open the consumer unit yourself.